40G parallel optics transceivers (40GBASE-SR4) can support 4x10G modes– this feature allow new parallel optics active equipment being compatible with existing 10G transceivers. MTP/MPO QSFP+ to SFP+ Fan-out Assemblies provide connections between single QSFP+ (40G transceiver with MTP/MPO interface) and 4 x SFP+ (10G transceivers with LC(DX) Interface). Parallel optics 40GBASE-XR4 uses 8 out of 12 MTP/MPO interface fibers transmitting 4 x Duplex (DX) channels (4 x Transmit and 4 x Receive). QSFP+ to SFP+ Fanout is 8 x Fibers MTP to LC(DX) Ruggedized Fan-out assembly. Assembly utilizes new miniature version of breakout module saving fibre management space and providing secure transition between cable and tails.
Feature
Space saving design
Provide narrow solution for high density application
High performance and reliability
Save installation time and labor
Next generation network proof
Application
Data center
Storage area network
Infiniband
Parallel optics
40GBASE-SR4 to 4x10GBASE-SR links
Fiber Type | SM Ferrule | SM Low-Loss Ferrule | MM Ferrule | MM Low-Loss Ferrule |
Insertion Typical (dB) | 0.35 | 0.20 | 0.35 | 0.20 |
Insertion Maximum (dB) | 0.70 | 0.35 | 0.60 | 0.35 |
Return Loss (dB) | PC≥50, UPC≥55, APC≥65 | |||
Male/Female | Male: With Pins Female: Without Pins | |||
Repeatability(dB) | ≤0.2 500 Times | |||
Operating Temperature(℃) | -40~+85 |